Çѱ¹¼öÀÚ¿øÇÐȸ / v.42, no.2, 2009³â, pp.171-176
On-site ¹æ½Ä ºø¹°°ü¸®¸¦ À§ÇÑ °ÇÃ๰ ÁöºØ¸éÀÇ À¯ÃâÆ¯¼º °æÇè½Ä ¼ö¸³
( An Experimental Runoff Formula in Building Roof Area for On-site Rainwater Management )
±è¿µÁø;Çѹ«¿µ;±è¿ëÇÏ;¹®Á¤¼ö; ³óÃÌÁøÈïû ±¹¸³³ó¾÷°úÇпø;¼­¿ï´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ°øÇкÎ;¼­¿ï´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ°øÇкÎ;¼­¿ï´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ°øÇкÎ;
 
ÃÊ ·Ï
º» ¿¬±¸´Â ÇöÁö(on-site) ºø¹°°ü¸®¿¡ ÇÊ¿äÇÑ ÁöºØ¸é ´©ÀûÀ¯Ãâ¿ëÀû ¿¹ÃøÀ» À§ÇÑ °æÇè½ÄÀ» Á¦¾ÈÇÏ¿´´Ù. °ÇÃ๰ ÁöºØ¸éÀº Á¼Àº ¸éÀûÀ¸·Î ÀÎÇØ ±âÁ¸ À¯ÃâÇØ¼® ±â¹ýÀÇ Àû¿ëÀÌ ¾î·Á¿î °ÍÀ¸·Î ÆÄ¾ÇµÇ¾úÀ¸¸ç, ÁöºØ¸é À¯ÃâÁ¶°ÇÀ» °í·ÁÇÑ °­¿ì±íÀÌ(D)-´©ÀûÀ¯Ãâ¿ëÀû(V)°£ÀÇ ÀÌ·ÐÀû °ü°è½ÄÀ» ¼ö¸³ÇÏ¿´´Ù. 2005³âºÎÅÍ 2007³â±îÁö 2³â°£ ½ÇÁ¦ °­¿ì·®°ú ÁöºØ¸éÀÇ À¯Ãâ¿ëÀûÀ» ÃøÁ¤ÇÏ¿© ÀÌ·ÐÀû °ü°è½ÄÀ¸·Î °è»êµÈ ´©ÀûÀ¯Ãâ¿ëÀû°ú ½ÇÃø ´©ÀûÀ¯Ãâ¿ëÀû ÀڷḦ ºñ±³ °ËÅäÇÏ¿´´Ù. ½ÇÃøÀÚ·áÀÇ ºÐ¼®°á°ú¸¦ ¹ÙÅÁÀ¸·Î ½Ã°£º° °­¿ì±íÀÌ º¯È­¿¡ µû¸¥ ´©ÀûÀ¯Ãâ¿ëÀûÀ» ¿¹ÃøÇÒ ¼ö ÀÖ´Â °æÇèÀû À¯Ãâ½ÄÀ» ¾ò¾ú´Ù. º» °æÇè½ÄÀ¸·Î °­¿ì°üÃø ÀÚ·á ¶Ç´Â °­¿ìÁÖ»óµµ¿Í ÁöºØ¸éÀÇ ¸éÀûÀ¸·ÎºÎÅÍ °£ÆíÇÏ°Ô ½ÇÁ¦¿¡ °¡±î¿î ´©ÀûÀ¯Ãâ¿ëÀûÀÇ ½Ã°£º° º¯È­¸¦ ¿¹ÃøÇÒ ¼ö ÀÖÀ¸¸ç, ÀÌ °á°ú´Â °¢Á¾ ºø¹°°ü¸®½Ã¼³ÀÇ ¿ë·® °áÁ¤Àº ¹°·Ð, ºø¹°°ü¸®½Ã¼³ ÅëÇØ ÁöºØ¸é¿¡¼­ µµ½Ã¹è¼ö°üÀ¸·Î À¯ÀԵǴ À¯·® º¯È­ ¿¹Ãø¿¡µµ Ȱ¿ëÀÌ °¡´ÉÇÒ °ÍÀÌ´Ù.
This study proposes an experimental formula for cumulative runoff analysis in building roof for on-site rainwater management. We can not find an appropriate method for roof runoff analysis because of its small area scale. A new runoff equation formula for rainfall depth(D) and cumulative runoff volume(V) is developed on roof runoff conditions. Reliability of the formula is verified with field experimental runoff monitoring for two years in two buildings of rainwater management system. This experimental runoff formula can root the cumulative runoff volume from roof area and rainfall depth, then develop reasonable inflow condition for rainwater retention tank design.
 
Ű¿öµå
ºø¹°°ü¸®½Ã¼³;°ÇÃ๰ ÁöºØ¸é;ÁöºØÀ¯Ãâ;´©ÀûÀ¯Ãâ;rainwater management system;building rooftop;roof runoff;cumulative runoff;RSD;
 