Çѱ¹¼öÀÚ¿øÇÐȸ / v.38, no.7, 2005³â, pp.537-544
|
°æ°è¿ä¼Ò¸ðÇüÀ» ÀÌ¿ëÇÑ ÁöÇÏ ÀúÀå°øµ¿ÀÇ ÁöÇϼö À¯ÀÔ·® ºÐ¼®
( Analysis of Groundwater Flow into Underground Storage Caverns by Using a Boundary Element Model ) |
Á¤ÀϹ®;ÀÌÁ¤¿ì;Á¶¿øÃ¶; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø¿¬±¸ºÎ;¿¬¼¼´ëÇб³ ´ëÇпø Åä¸ñ°øÇаú;¿¬¼¼´ëÇб³ °ø°ú´ëÇÐ Åä¸ñȯ°æ°øÇÐÀü°ø;
|
|
|
 |
|
|
ÃÊ ·Ï |
LPGµî °í¾Ð°¡½º¸¦ ÁöÇÏ¿¡ ÀúÀåÇÏ´Â ÀúÀå°øµ¿ÀÇ È¿°úÀûÀÎ °ü¸®¸¦ À§Çؼ´Â ÁöÇϼöÀ§, °¡½ºÀúÀå¾Ð, ¼ö¸·°ø ÁÖÀԾРµî¿¡ µû¸¥ °øµ¿ÁÖº¯ÀÇ À¯µ¿Àå ÇØ¼®, °øµ¿³»·ÎÀÇ ÁöÇϼö À¯ÀÔ·® ÇØ¼®À» ½Ç½ÃÇØ¾ß ÇÑ´Ù. ±âÁ¸¿¡´Â °øµ¿ÀÇ Á¤È®ÇÑ Çü»óÀ» ¹Ý¿µÇϱâ À§Çؼ À¯ÇÑ¿ä¼Ò¹ýÀÌ º¸ÆíÀûÀ¸·Î »ç¿ëµÇ¾î ¿ÔÀ¸³ª Çѹø ¼³Á¤ÇÑ À¯ÇÑ¿ä¼Ò¸ÁÀ¸·ÎºÎÅÍ °øµ¿ÀÇ ¼³°è¿ä¼Ò¸¦ º¯°æÇÏ´Â ÀÛ¾÷Àº ¼ö¿ùÇÏÁö ¾Ê¾Æ ¼³°èÀü´Ü°è¿¡¼ °øµ¿ ¹× ¼ö¸·½Ã¼³ÀÇ ´Ù¾çÇÑ ¹èÄ¡¿¡ µû¸¥ ¸ðÀǸ¦ ¼öÇàÇϴµ¥´Â ´Ù¼Ò ¹«¸®°¡ ÀÖ´Ù. ÀÌ·¯ÇÑ ºÒÆíÇÔÀº °æ°èºÎÀÇ Çü»ó°ú Á¶°Ç¸¸À¸·Î ³»ºÎÁ¡¿¡¼ÀÇ ¹ÌÁöº¯¼ö °è»êÀ» È¿°úÀûÀ¸·Î ¼öÇàÇÒ ¼ö ÀÖ´Â °æ°è¿ä¼Ò¹ýÀ» µµÀÔÇÔÀ¸·Î½á ±Øº¹ÇÒ ¼ö ÀÖ´Ù. µû¶ó¼ º» ¿¬±¸¿¡¼´Â ÁöÇϰøµ¿À¸·Î ¹è¼öµÇ´Â À¯ÀÔ·® »êÁ¤À» À§ÇØ °æ°è¿ä¼Ò¹ýÀ» ±Ù°£À¸·Î ÇÑ 2Â÷¿ø ÁöÇϼö È帧¸ðÇüÀ» ±¸¼ºÇÏ¿´À¸¸ç ÁöÇϰøµ¿À¸·Î ¹è¼öµÇ´Â Á¤È®ÇÑ À¯ÀÔ·® »êÁ¤À» À§ÇØ ÇØ¼®ÇØ ¹× ±âÁ¸ÀÇ À¯ÇÑ¿ä¼ÒÇØ¼®°á°ú¿Í ºñ±³ÇÏ¿© ¼öÄ¡ÇØ¼®ÀÇ Å¸´ç¼ºÀ» Á¦½ÃÇÏ¿´´Ù. ÀÌ ¸ðÇüÀº °øµ¿ÀÇ ¼³°è´Ü°è¿¡¼ ¼ö¸·°øÀÇ °£°Ý°ú ¹è¿ÇüÅÂ, °øµ¿ÀÇ ÃÖÀûÇü»óÀ» °áÁ¤Çϱâ À§ÇÑ ¸ðÀǽÇÇè¿¡¼ ±âÁ¸ÀÇ À¯ÇÑ¿ä¼ÒÇØ¼®ÀÇ ´ÜÁ¡À» ±Øº¹ÇÏ´Â ´ë¾ÈÀ¸·Î Ȱ¿ëµÉ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù. |
|
For the proper management of high pressurized gas storage caverns, analysis of groundwater flow field and inflow quantity according to the groundwater head, gas storage pressure and water curtain head should be performed. The finite element method has been widely used for the groundwater flow analysis surrounding underground storage cavern because it can reflect the exact shape of cavern. But the various simulations according to the change of design factors such as the width of water curtain, shape of cavern etc. are not easy when elements were set up. To overcome these limitations, two dimensional groundwater flow model is established based on the boundary element method which compute the unknown variable by using only the boundary shape and condition. For the exact computation of drainage rate into cavern, the model test is performed by using the exact solution and pre-developed finite element model. The test result shows that the model could be used as an alternative to finite element model when various flow simulations are needed to determine the optimizing cavern shape and arrangement of water curtain holes and so forth. |
|
Ű¿öµå |
ÁöÇÏÀúÀå°øµ¿;ÁöÇϼö À¯ÀÔ·®;°æ°è¿ä¼Ò¹ý;Underground storage cavern;Groundwater inflow;Boundary Element Method; |
|
|
|
 |
|
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.38, no.7, 2005³â, pp.537-544
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200531234566316)
¾ð¾î : Çѱ¹¾î |
|
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|