Çѱ¹¼öÀÚ¿øÇÐȸ / v.43, no.9, 2010³â, pp.781-787
¼ö¸é ¿µ»óÀÇ ½Ã°£Àû Çȼ¿³óµµº¯È­¸¦ ÀÌ¿ëÇÑ ¼öÀ§°èÃø¹æ¹ý
( Water Level Measurement Method Based on Temporal Variation of Water Surface Pixel Arrangement in Successive Images )
±Ç¼ºÀÏ;±è¿ø;ÀÌÂùÁÖ;±è½Âµ¿; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ.ÇØ¾ÈÇ׸¸¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ.ÇØ¾ÈÇ׸¸¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ.ÇØ¾ÈÇ׸¸¿¬±¸½Ç;(ÁÖ)ÇÏÀÌÅ×ÄÞ ½Ã½ºÅÛ;
 
ÃÊ ·Ï
º» ³í¹®¿¡¼­´Â ¸ñÀ򮂡ú ¼ö¸éÀÌ Æ÷ÇԵǵµ·Ï ÃÔ¿µµÈ µÎ Àå ÀÌ»óÀÇ ¿¬¼ÓÀûÀÎ ¿µ»óÀ¸·ÎºÎÅÍ ¼ö¸éÀÇ ¿¬¼ÓÀûÀÎ ¿òÁ÷ÀÓ¿¡ ÀÇÇØ Çȼ¿ÀÇ ³óµµº¯È­°¡ ¹ß»ýÇÏ´Â ÁöÁ¡À» ¼ö¸éÀ¸·Î ÀνÄÇÏ¿© ¼öÀ§¸¦ °èÃøÇÏ´Â ¹æ¹ýÀ» °³¹ßÇÏ¿´´Ù. ÀÌ ¹æ¹ýÀÇ ¼º´ÉÀ» °ËÁõÇϱâ À§ÇÏ¿© ¸ñÀÚÆÇÀÌ ¿À¿°µÈ °æ¿ì¿Í ¹°ÀÌ Åõ¸íÇÏ¿© ¹°¼ÓÀÌ Åõ½ÃµÇ´Â °æ¿ì¿¡ ´ëÇÏ¿© ½Ç³» ¹× ÇöÀå ½ÇÇèÀ» ½Ç½ÃÇÏ¿´´Ù. µÎ °æ¿ìÀÇ ½ÇÇè°á°ú¿¡¼­ ¸ðµÎ ±âÁ¸ ¼ö¸éÀνĹæ¹ý¿¡¼­´Â ¿À¿°µÈ ºÎºÐ°ú ¹°¼Ó Åõ½ÃµÈ ºÎºÐÀ» ¼ö¸éÀ¸·Î À߸ø ÀνÄÇÏ¿´À¸³ª, »õ·Î¿î ¹æ¹ý¿¡¼­´Â ¼ö¸éÀ» Á¤È®ÇÏ°Ô ÀνÄÇÏ¿© ¿Ã¹Ù¸¥ ¼öÀ§¸¦ ÃøÁ¤ÇÒ ¼ö ÀÖ¾ú´Ù. µû¶ó¼­ »õ·Î¿î ¼ö¸éÀνĹæ¹ýÀ» ÀÌ¿ëÇÏ¸é ±âÁ¸ ¿µ»ó¼öÀ§°èÀÇ ¼ö¸éÀÎ½Ä Á¤È®µµ¸¦ Çâ»ó½Ãų ¼ö ÀÖÀ» °ÍÀ¸·Î ±â´ëµÈ´Ù.
A new method for water level measurement method and its verification results are described. In this method, water surface in motion can be detected by temporal variation of pixel arrangement in successive digital images including the boundary between the staff gauge and the water surface. Laboratory and field tests were conducted for the two cases in which the staff gauge was contaminated by dirt or transparent due to clear water. The result shows water level can be accurately measure by this method for these two cases. It is expected that the accuracy of previous image stage gauge will be improved by the new method.
 
Ű¿öµå
¿µ»ó¼öÀ§°è;¼öÀ§°üÃø;Çȼ¿ÀÇ ³óµµº¯È­;¼öÀ§°è;image stage gauge;water level measurement;temporal variation of pixel arrangement;
 