¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.43, no.12, 2010³â, pp.1039-1050
À¯·®ÃøÁ¤ ¹æ¹ýÀÇ Á¤È®µµ ºÐ¼® -±«»ê´ï ÇÏ·ù ´Þõ Àû¿ë »ç·Ê¸¦ Áß½ÉÀ¸·Î-
( Inter-comparison of Accuracy of Discharge Measurement Methods - A Case Study Performed in the Dalcheon River Downstream of the Goesan Dam- )
ÀÌÂùÁÖ;±èµ¿±¸;±Ç¼ºÀÏ;±è¿ø; Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø °¨»ç½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ ÇØ¾ÈÇ׸¸¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ ÇØ¾ÈÇ׸¸¿¬±¸½Ç;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ÇÏõ ÇØ¾ÈÇ׸¸¿¬±¸½Ç;
 
ÃÊ ·Ï
º» ¿¬±¸¿¡¼­´Â ±«»ê´ï ÇÏ·ù ´Þõ¿¡¼­ 6°¡Áö Á÷Á¢ À¯·® ÃøÁ¤ ¹æ¹ý-À¯¼Ó¸éÀû¹ý, ºÀºÎÀÚ¹ý, ADCPÀ̵¿ÃøÁ¤¹ý, ADCPÁ¤Áö ÃøÁ¤¹ý, ÀüÀÚÆÄÇ¥¸éÀ¯¼Ó°è, LSPIV-À» Àû¿ëÇϰí, À̸¦ ´ï ¹æ·ù·® ¹× À¯¼Ó¸éÀû¹ý°ú ºñ±³ÇÔÀ¸·Î½á Á¤È®µµ¸¦ »óÈ£ Æò°¡ÇÏ¿´´Ù. À̸¦ À§ÇØ 2005³âºÎÅÍ 2010³â±îÁö ½Ç½ÃµÈ ÃÑ 39ȸÀÇ À¯·®ÃøÁ¤°á°ú°¡ ºÐ¼®µÇ¾ú´Ù. ´ï ¹æ·ù·®°úÀÇ ºñ±³ °á°ú, ºÀºÎÀÚ¹ýÀ» Á¦¿ÜÇÑ ³ª¸ÓÁö5°¡Áö ¹æ¹ýÀº Æò±Õ 6.2% À̳»ÀÇ Àý´ë°ª¿ÀÂ÷¸¦ ³ªÅ¸³Â´Ù. À¯¼Ó¸éÀû¹ý°ú ´Ù¸¥ 4°¡Áö¹æ¹ýÀ» ºñ±³ÇÒ °æ¿ì, ÀüÀÚÆÄÇ¥¸éÀ¯¼Ó°è´Â 7.35%, ³ª¸ÓÁö 3°¡Áö ¹æ¹ýÀº 6% À̳»ÀÇ Àý´ë°ª¿ÀÂ÷¸¦ ³ªÅ¸³Â´Ù. ºÀºÎÀÚ¹ýÀº ´ï ¹æ·ù·® ¹× À¯¼Ó¸éÀû¹ý°ú ºñ±³ÇÏ¿©µµ ¿ÀÂ÷ÀÇ ¹üÀ§°¡ Å©°Ô ³ªÅ¸³µ´Âµ¥, ÀÌ¿¡ ´ëÇØ¼­´Â Ãß°¡ÀûÀÎ °ËÁõÀÌ ÇÊ¿äÇÏ´Ù.
Relative accuracy of six discharge measurement methods-velocity-area method, rod-float method, ADCP moving-vessel method, ADCP fixed-vessel method, electromagnetic wave surface velocimeter (EWSV), LSPIV- is evaluated by comparing discharges measured by them with dam released discharges. Data from 39 times of concurrent discharge measurement campaigns are analyzed. Except the rod-float method, measured discharges show absolute errors less than 6.2% with dam discharges. When the four methods is evaluated by being compared with discharges measured with the conventional velocity-area method, discharges with electromagnetic wave surface velocimetry shows 7.35% of absolute errors and other three methods shows absolute errors less than 6%. The rod-float method, which shows large discrepancy compared with dam and velocity-area method, need complementary verification.
 
Ű¿öµå
À¯·®ÃøÁ¤;À¯·®ÃøÁ¤¹æ¹ý;Á¤È®µµ;discharge measurement;discharge measurement method;accuracy;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.43, no.12, 2010³â, pp.1039-1050
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201007049674083)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿