¶óÆæÆ®¦¢Ä«Æä¦¢ºí·Î±×¦¢´õº¸±â
¾ÆÄ«µ¥¹Ì Ȩ ¸í»çƯ°­ ´ëÇבּ¸½Ç޹æ Á¶°æ½Ç¹« µ¿¿µ»ó°­ÀÇ Çѱ¹ÀÇ ÀüÅëÁ¤¿ø ÇÐȸº° ³í¹®
ÇÐȸº° ³í¹®

Çѱ¹°Ç¼³°ü¸®ÇÐȸ
Çѱ¹°ÇÃà½Ã°øÇÐȸ
Çѱ¹µµ·ÎÇÐȸ
Çѱ¹»ý¹°È¯°æÁ¶ÀýÇÐȸ
Çѱ¹»ýÅÂÇÐȸ
Çѱ¹¼öÀÚ¿øÇÐȸ
Çѱ¹½Ä¹°ÇÐȸ
Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
Çѱ¹ÀÚ¿ø½Ä¹°ÇÐȸ
Çѱ¹ÀܵðÇÐȸ
Çѱ¹Á¶°æÇÐȸ
Çѱ¹Áö¹Ý°øÇÐȸ
Çѱ¹ÇÏõȣ¼öÇÐȸ
Çѱ¹È¯°æ»ý¹°ÇÐȸ
Çѱ¹È¯°æ»ýÅÂÇÐȸ

Çѱ¹¼öÀÚ¿øÇÐȸ / v.45, no.1, 2012³â, pp.65-73
ºø¹°Àú·ùÁ¶ÀÇ ºÐ»ê¹èÄ¡¿¡ µû¸¥ ÷µÎÀ¯Ãâ Àú°¨È¿°ú ºÐ¼® - M ¸¶À» »ç·Ê -
( The Effect of Decentralized Rainwater Tank System on the Reduction of Peak Runoff - A Case Study at M Village - )
Çѹ«¿µ;±Ý¼ÒÀ±;¹®Á¤¼ö;°ûµ¿±Ù; ¼­¿ï´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ°øÇкÎ;¼­¿ï´ëÇб³ °ø°ú´ëÇÐ °Ç¼³È¯°æ°øÇкÎ;Çѱ¹°Ç¼³±â¼ú¿¬±¸¿ø ¼öÀÚ¿ø.ȯ°æ¿¬±¸º»ºÎ;Æ÷½ºÄÚ °Ç¼³ ¹°È¯°æ»ç¾÷º»ºÎ;
 
ÃÊ ·Ï
±âÈĺ¯È­·Î ÀÎÇÑ ÁýÁßÈ£¿ì¿Í µµ½ÃÈ­·Î ÀÎÇÑ ºÒÅõ¼ö¸éÀÇ Áõ°¡´Â ¸¹Àº ¾çÀÇ ºñ¸¦ ¹Ù·Î Çϼö°ü°Å·Î À¯Ãâ½ÃÄÑ °ü°Å ¿ë·®Ãʰú·Î ÀúÁö´ëħ¼ö µîÀÇ ÇÇÇØ¸¦ ÀÏÀ¸Å²´Ù. Áö±Ý±îÁö´Â µµ½ÃÀÇ Ä¡¼ö¾ÈÀüµµ¸¦ ³ôÀ̱â À§ÇØ Çϼö°ü°Å¸¦ È®ÀåÇϰí, ºø¹°ÆßÇÁÀåÀÇ ¿ë·®À» Áõ´ëÇÏ´Â µîÀÇ ¹æ¹ýÀ» ÁַΠäÅÃÇϰí ÀÖÁö¸¸ ¸¹Àº ºñ¿ë°ú ½Ã°£ÀÇ ¼Òºñ¸¦ ÇÊ¿ä·Î ÇÏ¿© Çö½ÇÀûÀ¸·Î ºÒ°¡´É¿¡ °¡±õ´Ù. ÃÖ±Ù ¼Ò¹æ¹æÀçû°ú ¼ö¿ø½Ã´Â ±âÁ¸ ¿ì¼ö¹è¼ö ½Ã½ºÅÛÀÇ ÇѰ踦 º¸¿ÏÇÏ°í ´ëóÇϱâ À§ÇÑ »õ·Î¿î ´ë󹿾ÈÀ¸·Î ´Ù¸ñÀû ºÐ»êÇü ºø¹°°ü¸®¸¦ Á¦¾ÈÇϰí ÀÖ´Ù. º» ¿¬±¸¿¡¼­´Â ¼ö¿øÀÇ »ó½Àħ¼öÁö¿ªÀÎ M¸¶À»À» ¿¬±¸ ´ë»óÁö·ÎÇÏ¿© XP-SWMMÀ» ÀÌ¿ëÇÏ¿© ºÐ»êÇü ºø¹°Àú·ùÁ¶ Àû¿ë¿¡ µû¸¥ ÷µÎÀ¯Ãâ Àú°¨ È¿°ú¸¦ È®ÀÎÀ» À§ÇØ ¼³Ä¡ °³¼ö, ¹èÄ¡À¯Çü(¼³Ä¡À§Ä¡)À» ´Ù¸£°Ô ÇÏ¿© ÁýÁßÈ£¿ì½Ã Ä¡¼ö ¾ÈÀüµµ¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» ¸ðÀÇÇÏ¿´´Ù. ±× °á°ú 3,000 ¿ë·®ÀÇ ºø¹°Àú·ùÁ¶ ÇÑ °³¸¦ ¼³Ä¡ÇÒ °æ¿ì ÷µÎÀ¯ÃâÀÌ 15.5% Àú°¨µÇ¾úÀ¸¸ç, 500$m^3$ ¿ë·®Àú·ùÁ¶¸¦ 6°³¼³Ä¡ÇÏ¿´À» ¶§´Â÷µÎÀ¯ÃâÀÌ 28%Àú°¨µÇ¾ú´Ù. ºø¹°Àú·ùÁ¶ ¹èÄ¡À¯ÇüÀǰæ¿ì »ó·ù Áö¿ª¿¡ °¡Àå ºñÁß ÀÖ°Ô ¼³Ä¡Çϰí Áß·ù, ÇÏ·ù ¼øÀ¸·Î ºñÁßÀ» µÎ¾î ¼³Ä¡ÇÑ ÇüŰ¡ °¡Àå ÷µÎÀ¯Ãâ Àú°¨È¿°ú°¡ ÁÁ¾Ò´Ù. º» ¿¬±¸¿¡¼­ ¾ò¾îÁø ´Ù¸ñÀû ºÐ»êÇü ºø¹°°ü¸® ½Ã½ºÅÛÀÇ ÇØ¼®¹æ¹ýÀº ±âÈĺ¯È­¿¡ ´ëºñÇÏ¿© Çϼö°ü°Å ¿ë·®À» Áõ¼³ÇÏÁö ¾Ê°íµµ Ä¡¼ö ¾ÈÀüµµ¸¦ Áõ°¡½Ãų ¼ö ÀÖ´Â ½Ã½ºÅÛÀ» °æÁ¦ÀûÀ¸·Î ¼³°èÇϰí, ±× È¿°ú¸¦ ¿¹ÃøÇϴµ¥ »ç¿ëµÉ ¼ö ÀÖ´Ù.
Recently climate change and increase of surface runoff caused the urban flooding. Traditional way of dealing with urban flooding has been to increase the sewer capacity or construction of pumping stations, however, it is practically almost impossible because of time, money and traffic problems. Multipurpose DRMS (Decentralized Rainwater Management System) is a new paradigm proposed and recommended by NEMA (National Emergency Management Agency) for both flood control and water conservation. Suwon City has already enacted the ordinance on sound water cycle management by DRMS. In this study, a flood prone area in Suwon is selected and analysis of DRMS has been made using XP-SWMM for different scenarios of RT installation with same total rainwater tank volume and location. Installing one rainwater tank of 3,000$m^3$ can reduce the peak flow rate by 15.5%. Installing six rainwater tanks of 500$m^3$ volume in the area can reduce the peak flow rate by 28%. Three tanks which is concentrated in the middle region can reduce peak rate more than evenly distributed tanks. The method and results found from this study can be used for the design and performance prediction of DRMS at a flood prone area by supplementing the existing sewer system without increase of the sewer capacity.
 
Ű¿öµå
±âÈĺ¯È­;´Ù¸ñÀû ºÐ»êÇüºø¹°°ü¸®;ºÐ»êÇü ºø¹°°ü¸®;ºø¹°Àú·ùÁ¶;÷µÎÀ¯ÃâÀú°¨;Climate change;Multipurpose Decentralized Rainwater Management System (MDRMS);Decentralized Rainwater Management System (DRMS);rainwater tank;Peak flow rate reduction;
 
Çѱ¹¼öÀÚ¿øÇÐȸ³í¹®Áý / v.45, no.1, 2012³â, pp.65-73
Çѱ¹¼öÀÚ¿øÇÐȸ
ISSN : 1226-6280
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO201208040010027)
¾ð¾î : Çѱ¹¾î
³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø
¸ñ·Ïº¸±â
ȸ»ç¼Ò°³ ±¤°í¾È³» ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ Ã¥ÀÓÀÇ ÇѰè¿Í ¹ýÀû°íÁö À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý °ÅºÎ °í°´¼¾ÅÍ
   

ÇÏÀ§¹è³ÊÀ̵¿