Çѱ¹°Ç¼³°ü¸®ÇÐȸ / v.5, no.6, 2004³â, pp.212-217
|
ź¼Ò¼¶À¯ÆÇÀ¸·Î º¸°µÈ ö±ÙÄÜÅ©¸®Æ® º¸ÀÇ º¸°¼º´É¿¡ °üÇÑ ¿¬±¸
( A Study on Structural Performance Evaluation of RC Beams Strengthened with CFRP Plate ) |
| ±èÁß±¸; °í·ÁÁ¤°øÁÖ½Äȸ»ç;
|
|
|
 |
|
| |
| ÃÊ ·Ï |
| ÀÌ ¿¬±¸´Â °°Àº À§Ä¡¿¡ Èû¸ð¸àÆ®¿Í Àü´Ü·ÂÀÌ ÃÖ´ë°¡ µÇ´Â ö±ÙÄÜÅ©¸®Æ® º¸¿¡ ´ëÇÏ¿© ÈÚ¸ð¸àÆ® º¸°À» ½Ç½ÃÇÏ´Â °æ¿ì, ź¼Ò ¼¶À¯ÆÇÀÇ µÎ²²¿Í ÇÏÁßÁ¡ ºÎÀ§ ¹× ź¼Ò¼¶À¯ÆÇÀÇ ³¡ºÎºÐÀ» °¨½Î´Â ź¼Ò¼¶À¯½¬Æ®ÀÇ °ã¼ö¸¦ º¯¼ö·Î ÇÏ¿© º¸ÀÇ ±¸Á¶Àû °Åµ¿À» ½ÇÇèÇÏ¿´´Ù. ź¼Ò¼¶À¯ÆÇÀÇ µÎ²²ÀÇ Áõ°¡¿¡ µû¶ó ³»·ÂÀÌ Áõ°¡ÇÏ¿´À¸³ª ¼±ÇüÀûÀ¸·Î ºñ·ÊÇÏÁö ¾Ê¾ÒÀ¸¸ç, ÇÏÁßÁ¡¿¡ °¨½Ñ ź¼Ò¼¶À¯½¬Æ®ÀÇ ¿µÇâÀº ¶Ñ·ÇÇÏ°Ô ³ªÅ¸³ªÁö ¾Ê¾Ò´Ù ÀÌ ´Â º¸°½ÃÇèÀÇ ÁÖµÈ ÆÄ±«°¡ ź¼Ò¼¶À¯ÆÇÀÇ ÆÄ´ÜÀÌ ¾Æ´Ñ ÇÏÁßÁ¡ ÁÖÀ§¿¡¼ÀÇ ÈÝ-Àü´Ü±Õ¿¿¡¼ºÎÅÍ ÃþºÐ¸®°¡ ½ÃÀ۵Ǿú°í ÇÏÁßÁ¡À» ź¼Ò¼¶À¯½¬Æ®·Î °¨½Ñ °æ¿ì ÈÝ-Àü´Ü±Õ¿ ź¼Ò¼¶À¯½¬Æ®ÀÇ ¹Ù±ù ºÎºÐÀ¸·Î À̵¿Çϱ⠶§¹®ÀÌ´Ù. ¶ÇÇÑ Åº¼Ò¼¶À¯ÆÇ ´ÜºÎ¿¡ Á¤Âø¿ëÀ¸·Î ½Ã°øÇÑ Åº¼Ò¼¶À¯½¬Æ®´Â ÇÏÁßÁ¡¿¡¼ ¹ß»ýÇÑ Ã뼺ÆÄ±«·Î ÀÎÇÏ¿© Å« È¿°ú¸¦ ³ªÅ¸³»Áö ¸øÇÏ¿´´Ù. ±×·¯¹Ç·Î ÀçÇÏ»óÅ¿¡ µû¸¥ ¼³°è¹æ¹ýÀ» ´Ù¸£°Ô ÇÒ Çʿ䰡 ÀÖÀ¸¸ç, ƯÈ÷ °°Àº À§Ä¡¿¡¼ ÈÚ¸ð¸àÆ®¿Í Àü´Ü·ÂÀÌ ÃÖ´ë°¡ µÇ´Â °æ¿ì ź¼Ò¼¶À¯ÆÇÀÇ À¯È¿ µÎ²²´Â ÃÖ´ë 0.6mm·Î ÇÏ°í ¹«º¸°º¸ÀÇ ÈÚ¸ð¸àÆ®¿¡ ´ëÇÑ º¸°µÈ º¸ÀÇ ÈÚ¸ð¸àÆ® ºñ´Â 1.5-2.0À¸·Î Á¦ÇÑÇÏ´Â °ÍÀÌ ¹Ù¶÷Á÷Çϸç, 0.6mmÀÌ»óÀÇ Åº¼Ò¼¶À¯ÆÇÀ» »ç¿ëÇϱâ À§ÇÏ¿© ź¼Ò¼¶À¯½¬Æ®·Î ÇÏÁßÁ¡À» º¸°ÇÏ´Â °æ¿ì ¹«º¸°º¸ ÈÚ¸ð¸àÆ®ÀÇ 1.5 ¹è°¡ µÇ´Â À§Ä¡ÀÌ»ó ź¼Ò¼¶À¯½¬Æ®¸¦ ¿¬ÀåÇÏ´Â °ÍÀÌ ¹Ù¶÷Á÷ÇÏ´Ù. |
|
| Carbon fiber reinforced plastic(CFRP) plate Is one of the alterative materials for soengthening of reinforced and prestressed connote members due to excellent strength and light weight In this paper, the behavior of beams strengthened with CFRP plate and CFS(Carbon fiber sheet) is observed and analyzed from the test results. Especially specimens with thick plate is tested when large moment and large shear lone appear in same position. The main failure mode is a peeling-off of the CFRP plate near the loading points due to flexural-shear crack, Because of this failure mode, failure load is not linearly proportional to the thickness of CFRP plates. When beam is wrapped with CFS around oª«y loading point it does not influence on the failure loads. Depending on the loading pattern, it is necessary to consider different design criteria for reinforced concrete members with external reinforcement. When line moment and large shear force appear in same location, maximum thickness may limit to 0.6mm and ratio between moment of strengthened beam and moment of unstrengthened beam is proposed 1.5-2.0. In order to use the plate of thicker than 6mm, CFS may be extended to the location which moment of strengthened beam is 1.5 times than moment of unstrengthened beam. |
| |
| Ű¿öµå |
| ź¼Ò¼¶À¯ÆÇ;ź¼Ò¼¶À¯½¬Æ®;¿¡Æø½Ã ¸ôÅ»;º¸°;¹Ú¸®;ÈÚ-Àü´Ü ±Õ¿;beam;CFRP Plate;CFS;epoxy mortar;strengthening;delamination;flexural-shear crack; |
| |
|
|
 |
|
Çѱ¹°Ç¼³°ü¸®ÇÐȸ³í¹®Áý / v.5, no.6, 2004³â, pp.212-217
Çѱ¹°Ç¼³°ü¸®ÇÐȸ
ISSN : 2005-6095
UCI : G100:I100-KOI(KISTI1.1003/JNL.JAKO200404840809904)
¾ð¾î : Çѱ¹¾î |
|
| ³í¹® Á¦°ø : KISTI Çѱ¹°úÇбâ¼úÁ¤º¸¿¬±¸¿ø |
|
|
|
|
|
|